Secured Shopping
Best security features
Nationwide Shipping
Nationwide Shipping
Manufacturer Warranty
Manufacturer Warranty
APC Galaxy VS UPS 15kW 400V, 1 internal 7Ah smart modular battery string, expandable to 2, Start-up 5x8 ( GVSUPS15KB2HS )
- Stock: 1
- Model: GVSUPS15KB2HS
- Weight: 270.00kg
- Dimensions: 100.00cm x 65.00cm x 170.00cm
- SKU: GVSUPS15KB2HS
Products Sold: 0
Product Views: 4539
MYR72,504.00
Ex Tax: MYR72,504.00
- Highly efficient, easy-to-deploy 15kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data ...
- Includes: Battery modules ship installed, Dust filter, EcoStruxure IT ready (UPS), Installation guide, Integrated network management, Power modules ship installed ...
GVSUPS15KB2HS Features
Key Features
Output power capacity15.0kWatts / 15.0kVAOutput Connections(1) Hard wire 5-wire (3P + N + E) (Battery Backup)Nominal Output Voltage400V 3PHNominal Input Voltage400V 3PHInput ConnectionsHard wire 3-wire (3P + E), Hard wire 5-wire (3P + N + E)Maximum Input Current27.0AGalaxy VS UPS 15kW 400V, 1 internal 7Ah smart modular battery string, expandable to 2, Start-up 5x8Highly efficient, easy-to-deploy 15kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5x8 start-up service and 1 smart modular battery string, expandable to 2 strings for extended runtime. Runtime charts available in the Documents tab.Includes: Battery modules ship installed, Dust filter, EcoStruxure IT ready (UPS), Installation guide, Integrated network management, Power modules ship installed, Start-up serviceGalaxy VS Features & Benefits
Availability
Flexible DC busOptimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.Built-in backfeed protectionFull built-in backfeed contactor ensures that no electricity is sent back to the grid.Parallel-capacity capabilityIncreases total power capacity by using multiple uninterruptible power supplies simultaneously.Embedded Network Management CardAllows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.Parallel-redundant capabilityPowers the connected equipment with multiple uninterruptible power supplies and redundant fan design to increase system redundancy.Total cost of Ownership
Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.Robust operationNo power derating in kW up to 40°C or 104°F.Wide input voltage rangeDesigned for harsh electrical environments to save battery life.Compact UPSHigh-density technology and full front access make this UPS a footprint saver well suited for confined spaces.Compatible with Galaxy Lithium-ion Battery CabinetsReduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability. Galaxy VS UPSs for external batteries are compatible with Galaxy Lithium-ion Battery Cabinets.ECOnversion modeOperating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.High efficiency in double conversion modeConsistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.Serviceability
EcoStruxure IT ExpertFrom your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries. To learn more, visita target="_blank" href="http://www.ecostruxureit.com" ecostruxureit.com /a . Front-access servicingSimplifies installation and UPS maintenance while minimizing space requirements.Modular UPS designProvides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.Multiple levels of service offersWith the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.Technical Specifications
Output
Max Configurable Power (Watts)15.0kWatts / 15.0kVAOutput Voltage DistortionLess than 3 %Output Frequency (sync to mains)50 Hz +/- 0.1 % For 50 Hz nominal Unsynchronised, 50 Hz Sync to mains, 60 Hz +/- 0.1 % For 60 Hz nominal Unsynchronised, 60 Hz Sync to mainsOther Output Voltages380 V, 415 VLoad Crest Factor2.5Waveform typeSine waveOverload Operation10 minutes at 125% and 60 seconds at 150%Output Voltage THD< 1% linear load and < 3% non-linear loadOutput Voltage Tolerance+/-1% after 50msBypassBuilt-in static bypassInput
Input frequency40 - 70 HzInput voltage range for main operations340 - 460 (400 V)VInput Total Harmonic DistortionLess than 3 % for full loadOther Input Voltages380 V, 415 VMaximum Short Circuit Withstand (Icw)65.0kAmpsInput Power Factor at Full Load0.99Batteries & Runtime
Battery typeInternal modular battery, VRLANominal Battery Voltage480 VEnd of Discharge Maximum Battery Current41.0AEnd of Discharge Battery Voltage384 V DCEfficiencyCommunications & Management
Interface Port(s)GVS_350mm_AirFilter, GVS_350mm_Seismic, GVS_ParallelControl panelTouch screen LCD user interfaceAudible AlarmAudible and visible alarms prioritized by severityAvailable SmartSlot™ Interface Quantity1Physical
Maximum Height1485MM, 148.5CMMaximum Width333MM, 33.3CMMaximum Depth847MM, 84.7CMNet Weight245.0KGColorWhiteEnvironmental
Operating Temperature0 - 40 °COperating Relative Humidity0 - 95 (Non-condensing) %Operating Elevation0 - 1000.05metersStorage Temperature-15 - 40 °CStorage Relative Humidity10 - 80 (Non-condensing) %Storage Elevation0 - 3048metersAudible noise at 1 meter from surface of unit65.0dBAOnline thermal dissipation1761.0BTU/hrProtection ClassIP20Conformance
ApprovalsCSA C22.2 No 107.3, EN/IEC 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 60721-4-2 level 2M2, UL 1778 5th editionStandard warranty1 year on-site repair or replace with factory authorized Start-UpSustainable Offer Status
RoHSCompliantOther Environmental ComplianceChina RoHS
Tags:
galaxy
, 15kw
, 400v
, internal
, smart
, modular
, battery
, string
, expandable
, start
, gvsups15kb2hs
, uninterruptible
, power
, supply
, Galaxy
, 15kW
, 400V
,
, string
,
, Start-up
, GVSUPS15KB2HS
, Uninterruptible Power Supply (UPS)